Penetrating damp in buildings
Damp in buildings may be apparent from:
- Damp patches...
- Mould growth, which is a cause of respiratory allergies.
- Mildew, salts, staining and ‘tide marks’.
- Damage to surface finishes.
- Corrosion and decay of the building fabric.
- Slip hazards.
- Frost damage.
- Poor performance of insulation.
- Damage to equipment, or electrical failure.
The most common causes of persistent damp in buildings are:
Penetrating damp is moisture that penetrates laterally through the fabric of a building from the outside, typically as a result of; leaking roofs or pipework, blocked or damaged guttering, cracks in walls, and so on.
Penetrating damp is most common high on south-west facing walls that are exposed to driving rain. It is particularly common in older buildings which do not have a cavity in the external wall construction. Properly constructed cavity walls should drain penetrating water back to the outside through ‘weep holes’. However, penetrating damp can occur in cavity wall constructions where insulation has not been properly installed, where cavities include obstructions, where cavities have been incorrectly filled or where wall ties have been incorrectly installed.
Damp can often be seen visually, but diagnosing the cause can be difficult and can involve specialist advise and equipment, such as; electrical resistance meters (although the presence of salts will affect resistance as well as damp – see Rising damp for more information), carbide meters, thermal imaging cameras, and so on.
It is only when the source has been identified that the problem can be tackled. This may be as simple as repairing damaged items, such as; damage to flashing, missing or broken slates or tiles, damaged pipework, cracks in walls, old or damaged sealants, damage to chimneys, parapets and other parts of the building that are difficult to see, deteriorating pointing and so on. However, where problems are concealed, such as incorrectly constructed cavities, they can be very difficult and disruptive to rectify.
There are a number of external treatments available to prevent penetrating damp, such as cladding external walls and the use of colourless water-repellent treatments. However, this may just conceal the problem, and increasing the impermeability of external walls could increase the likelihood of surface condensation inside the building or interstitial condensation within the structure itself.
Breathable treatments are available, but again, it is important that the source of the problem is tackled.
Treatment generally also involves remedial work to any corroded or decayed elements of the building fabric, such as hacking off and replacing existing plaster, replacing timbers, re-decoration, and so on.
NB Guidance on the code of practice for property flood resilience, published by CIRIA in 2021, defines water ingress as: ‘The seepage or entry of water into an area it should not be in.’
See also: Leaks in buildings.
[edit] Related articles on Designing Buildings Wiki
- Assessing moisture in porous building materials.
- Breather membrane.
- Building damp-free cavity walls.
- Carbide meter.
- Cold bridge.
- Condensation.
- Damp.
- Damp-proof course.
- Damp proofing.
- Defects in brickwork
- Defects in stonework.
- Dew point.
- Diagnosing the causes of dampness (GR 5 revised).
- Does damp proofing work?
- Efflorescence.
- Flashing.
- Humidity.
- Insulation.
- Interstitial condensation.
- Leaks in buildings.
- Mould growth.
- Rising damp.
- Rising damp in walls - diagnosis and treatment (DG 245).
- Spalling.
- Tanking.
- Treating brickwork with sealant or water repellent.
- Understanding dampness.
- Weathertight.
Featured articles and news
Do you take the lead in a circular construction economy?
Help us develop and expand this wiki as a resource for academia and industry alike.
Warm Homes Plan Workforce Taskforce
Risks of undermining UK’s energy transition due to lack of electrotechnical industry representation, says ECA.
Cost Optimal Domestic Electrification CODE
Modelling retrofits only on costs that directly impact the consumer: upfront cost of equipment, energy costs and maintenance costs.
The Warm Homes Plan details released
What's new and what is not, with industry reactions.
Could AI and VR cause an increase the value of heritage?
The Orange book: 2026 Amendment 4 to BS 7671:2018
ECA welcomes IET and BSI content sign off.
How neural technologies could transform the design future
Enhancing legacy parametric engines, offering novel ways to explore solutions and generate geometry.
Key AI related terms to be aware of
With explanations from the UK government and other bodies.
From QS to further education teacher
Applying real world skills with the next generation.
A guide on how children can use LEGO to mirror real engineering processes.
Data infrastructure for next-generation materials science
Research Data Express to automate data processing and create AI-ready datasets for materials research.
Wired for the Future with ECA; powering skills and progress
ECA South Wales Business Day 2025, a day to remember.
AI for the conservation professional
A level of sophistication previously reserved for science fiction.
Biomass harvested in cycles of less than ten years.
An interview with the new CIAT President
Usman Yaqub BSc (Hons) PCIAT MFPWS.
Cost benefit model report of building safety regime in Wales
Proposed policy option costs for design and construction stage of the new building safety regime in Wales.
Do you receive our free biweekly newsletter?
If not you can sign up to receive it in your mailbox here.